    • https://kb.netapp.com/on-prem/solidfire/hardware_Kbs/All_storage_nodes_report_SensorReadingFailed_bmcTestFailed_and_not_resolved_by_power_drain
      Applies to H410S (H300S, H500S, H700S) All storage nodes in cluster report SensorReadingFailed, bmcTestFailed Cluster alerts, and those are not resolved. Power Drain temporary resolve the issue, but t...Applies to H410S (H300S, H500S, H700S) All storage nodes in cluster report SensorReadingFailed, bmcTestFailed Cluster alerts, and those are not resolved. Power Drain temporary resolve the issue, but the issue reoccur after a while. Removing ethernet cable from BMC Port and Power Drain resolve the Alerts. Issue All storage nodes in cluster report SensorReadingFailed, bmcTestFailed Cluster alerts.