    About 1 results
    • https://kb.netapp.com/on-prem/ontap/OHW/OHW-KBs/Node_reboots_with_NVDIMM_in_ERROR_condition
      AFF A800, AFF C800, ASA A800, ASA C800 AFF A400, AFF C400, ASA A400, ASA C400 Node goes down and the below errors are observed in the console logs: DIMM F0: NVDIMM in ERROR condition (status = 0000080...AFF A800, AFF C800, ASA A800, ASA C800 AFF A400, AFF C400, ASA A400, ASA C400 Node goes down and the below errors are observed in the console logs: DIMM F0: NVDIMM in ERROR condition (status = 00000801). [nvdimm.nvmem.destage.failure:ALERT]:NVMEM subsystem fail to start or complete destage process, please check battery or NVDIMM.. Uncorrectable ECC error may be reported in the BMC event logs: c1a | 05/02/2024 | 05:55:49 | Power Unit #0xb2 | Power reset | Asserted | from channel 15