Skip to main content
NetApp Knowledge Base

Search

  • Filter results by:
    • View attachments
    Searching in
    About 1 results
    • https://kb.netapp.com/on-prem/ontap/OHW/OHW-KBs/Disk_bay_showing_as_NONCRITICAL
      Single disk bay reporting status NONCRITICAL Storage show fault shows the shelf condition as noncritical ::> node run -node node_name -command storage show fault Disk Elements: Element Status Status B...Single disk bay reporting status NONCRITICAL Storage show fault shows the shelf condition as noncritical ::> node run -node node_name -command storage show fault Disk Elements: Element Status Status Bytes Status Descriptions 0 [Bay 0]: OK 01,00,00,00 1 [Bay 1]: OK 01,01,00,00 13 [Bay 13]: OK 01,0D,00,00 14 [Bay 14]: NONCRITICAL 03,0E,00,00 Reseat of disk does not clear the error Disk replacement does not clear the error Attempted reseating both IOMs individually but issue remains