Skip to main content
NetApp Knowledge Base

Search

  • Filter results by:
    • View attachments
    Searching in
    About 1 results
    • https://kb.netapp.com/on-prem/solidfire/Element_OS_Kbs/After_12_5_upgrade_cluster_reports_hardwareConfigMismatch_MEMORY_GB_should_be_256_but_is_240
      After an upgrade to Element 12.5 or 12.7 a cluster fault is triggered: hardwareConfigMismatch MEMORY_GB should be >= 256 but is 240 In the System Health Event Log (SEL ) an event is reported as Failin...After an upgrade to Element 12.5 or 12.7 a cluster fault is triggered: hardwareConfigMismatch MEMORY_GB should be >= 256 but is 240 In the System Health Event Log (SEL ) an event is reported as Failing DIMM: DIMM location (Correctable memory component found) (P2-DIMMF1) - Assertion From the BMC GUI, hardware information shows the DIMM with half capacity During node boot phase it reports as Failing DIMM: DIMM location (Correctable memory component found) P2-DIMMF1