    • https://kb.netapp.com/on-prem/E-Series/SANtricity-OS-KBs/E-Series_controller_may_reboot_due_to_interaction_with_Brocade_FC_switch
      Applies to E-Series controllers using 16Gb or 32Gb fibre channel host interfaces Controllers running firmware prior to 8.30.4X.XX, 11.30.4, 8.40.1X.XX, and 11.40.1 Brocade FC switch connected to contr...Applies to E-Series controllers using 16Gb or 32Gb fibre channel host interfaces Controllers running firmware prior to 8.30.4X.XX, 11.30.4, 8.40.1X.XX, and 11.40.1 Brocade FC switch connected to controllers In rare cases, a controller may reboot when connected to a Brocade switch and running a controller firmware version less than listed above. Controller may report the following in the exception log: Page Fault errCode: 0 pc: 0xffffffff83a2b87a (with the following contained in the backtrace)