7MTT transfer fails due to TDP destination volume on the cluster
Applies to
- 7-mode Transition Tool (7MTT)
- TDP (Transition Data Protection)
Issue
- While performing the migration, encountered 7-mode transition error:
Last Transfer Error: Transition data-protection destination volume "svm1" cannot be on a FabricPool.
- The destination cluster has a composite aggregate.
cluster1::> run -node cluster1-01 -command aggr status -v
Aggr State Status Options
data_aggr1 online raid_dp, aggr root, diskroot, nosnap=on, raidtype=raid_dp,
64-bit raidsize=24, ignore_inconsistent=off,
snapmirrored=off, resyncsnaptime=5,
fs_size_fixed=off, ha_policy=cfo,
hybrid_enabled=off, percent_snapshot_space=5%,
nearly_full_threshold=97%, full_threshold=96%,
free_space_realloc=off, compacted,
composite=on, enable_cold_data_reporting=off,
enable_auto_cold_data_reporting=off