HCI compute node vmnic port down due to SFP failure
Applies to
Issue
- One vmnic port on an HCI compute node remains down after host reboot.
- No issues detected from the connected switch side.
nicinfo.sh.txtfrom ESXi bundle:
Name PCI Device Driver Admin Status Link Status Speed Duplex MAC Address MTU Description
------ ------------ ---------- ------------ ----------- ----- ------ ----------------- ---- -----------
vmnic0 0000:3b:00.1 nmlx5_core Up Up 10000 Full XX:XX:XX:XX:XX:XX 9000 Mellanox Technologies MT27710 Family [ConnectX-4 Lx]
vmnic1 0000:19:00.1 nmlx5_core Up Up 10000 Full XX:XX:XX:XX:XX:XX 9000 Mellanox Technologies MT27710 Family [ConnectX-4 Lx]
vmnic2 0000:18:00.0 ixgben Up Up 10000 Full XX:XX:XX:XX:XX:XX 1500 Intel(R) Ethernet Controller 10G X550
vmnic3 0000:18:00.1 ixgben Up Up 10000 Full XX:XX:XX:XX:XX:XX 1500 Intel(R) Ethernet Controller 10G X550
vmnic4 0000:19:00.0 nmlx5_core Up Down 0 Half XX:XX:XX:XX:XX:XX 9000 Mellanox Technologies MT27710 Family [ConnectX-4 Lx]
vmnic5 0000:3b:00.0 nmlx5_core Up Up 10000 Full XX:XX:XX:XX:XX:XX 9000 Mellanox Technologies MT27710 Family [ConnectX-4 Lx]
vmkernel.logentry:
2025-12-12T10:35:50.968Z cpu9:2098318)<NMLX_INF> nmlx5_core: vmnic4: nmlx5_en_UplinkLinkStateSetOS - (nmlx5_core_en_uplink.c:4764) Changing link status from UP Full Duplex 10000 to DOWN Half Duplex 0