CVO Upgrade paused on error 'node is not in connected state after giveback'
Applies to
- Cloud Volumes ONTAP (CVO)
- Automated Non-Disruptive Upgrade (ANDU)
Issue
- CVO upgrade was paused with error :
::*> cluster image show-update-progress
Estimated Elapsed
Update Phase Status Duration Duration
-------------------- ----------------- --------------- ---------------
Pre-update checks completed 00:10:00 00:01:05
ONTAP updates paused-on-error 01:32:00 00:29:14
Details:
Node name Status Status Description
-------------------- ----------------- --------------------------------------
node-01 waiting
node-02 failed Error: Node "node-02" is not in "connected" state after giveback.
Action: Use "storage failover show" command to verify node "node-02"
is in the "connected" state, and then use the "cluster image resume-update"command to resume update.
- EMS reports the below error :
[node-01: upgrademgr: upgrademgr.update.pausedErr:error]: The automated update of the cluster has been paused due to the following reason: Node "node-01": Error: {Node "node-02" is not in "connected" state after giveback.}, Action: {Use the "storage failover show" command to verify that node "node-02" is in the "connected" state, and then use the "cluster image resume-update" command to resume the update.}.