Issue

  • During upgrade to StorageGRID 11.4.0, the StorageGRID Appliance hangs at "Rebooting":

sn_rebooting.png

[2021-07-12 03:06:14+00:00 SGA] WARNING -- Not all volumes are present in /dev/mapper CHECK MULTIPATH CONFIG
[2021-07-12 03:06:14+00:00 SGA] INFO -- Missing volume mappings; rewriting multipath.conf and recalculating in 15 seconds
...
[2021-07-12 03:06:16+00:00 SGA] INFO -- Wrote multipath config file.
[  151.131520] scsi 6:0:0:7: Power-on or device reset occurred
[  153.754420] scsi 7:0:0:7: Power-on or device reset occurred
[2021-07-12 03:06:25+00:00 SGA] INFO -- Flushing multipath devices
[2021-07-12 03:06:25+00:00 SGA] INFO -- Clearing dm devices
[2021-07-12 03:06:25+00:00 SGA] INFO -- Restarting multipath-tools daemon
[2021-07-12 03:06:40+00:00 SGA] INFO -- Reloading multipath devices
...
[2021-07-12 03:06:56+00:00 SGA] WARNING -- Not all volumes are present in /dev/mapper CHECK MULTIPATH CONFIG
[2021-07-12 03:06:56+00:00 SGA] INFO -- Missing volume mappings; rewriting multipath.conf and recalculating in 15 seconds
...
[2021-07-12 03:07:37+00:00 SGA] WARNING -- Not all volumes are present in /dev/mapper CHECK MULTIPATH CONFIG
[2021-07-12 03:07:37+00:00 SGA] INFO -- Missing volume mappings; rewriting multipath.conf and recalculating in 15 seconds
...
[2021-07-12 03:08:18+00:00 SGA] WARNING -- Not all volumes are present in /dev/mapper CHECK MULTIPATH CONFIG
[2021-07-12 03:08:18+00:00 SGA] INFO -- Missing volume mappings; rewriting multipath.conf and recalculating in 15 seconds
...
[2021-07-12 03:08:59+00:00 SGA] WARNING -- Not all volumes are present in /dev/mapper CHECK MULTIPATH CONFIG
[2021-07-12 03:08:59+00:00 SGA] ERROR -- Mappings do not exist!
[2021-07-12 03:08:59+00:00 SGA] /usr/local/bin/WaitForEOS.py returned non-zero exit code; forcing install
[2021-07-12 03:08:59+00:00 SGA] [root@StorageGRID-PGE:/root] >>> rm -f /tmp/maintenance.mode
[2021-07-12 03:08:59+00:00 SGA] Enable CFW download on E-series as we are in PGE mode.
...
[2021-07-12 03:08:59+00:00 SGA] [2021-07-12T03:08:59.775] -    INFO -- Not loading synced data from SG OS LUN. Device /dev/mapper/StorageGRID-SG-OS-part1 does not exist
...
[2021-07-12 03:10:06+00:00 SGA] [root@StorageGRID-PGE:/usr/local/lib/pge-mgmt-api] >>> sleep 1
[2021-07-12 03:10:07+00:00 SGA] [root@StorageGRID-PGE:/usr/local/lib/pge-mgmt-api] >>> mount /dev/sda1 /mnt/pge-inac-part
[  375.549105] EXT4-fs (sda1): mounted filesystem with ordered data mode. Opts: (null)
[2021-07-12 03:10:07+00:00 SGA] [root@StorageGRID-PGE:/usr/local/lib/pge-mgmt-api] >>> umount /mnt/pge-inac-part

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.