Skip to main content
NetApp Knowledge Base

Element cluster fails to report to ActiveIQ due to out of memory condition in the mNode AIQ collector service

Views:
254
Visibility:
Public
Votes:
0
Category:
netapp-hci
Specialty:
hci
Last Updated:

Applies to

  • HCI or AFA clusters running Element Software and configured to report to ActiveIQ
  • Element management node (mNode) version 11.3 or above running management services 2.15.28
  • Hybrid Cloud Control (HCC) version 2.15

Issue

Symptoms can vary across the storage cluster (AFA or HCI storage nodes running Element Software) and HCI compute nodes.

For Storage Clusters:

  • the storage cluster is no longer reporting to ActiveIQ

For Compute nodes:

  • the compute nodes are no longer reporting to ActiveIQ
  • the compute nodes may not show in Hybrid Cloud Control (HCC) on the mNode

The common denominator for both environments is an out of memory error in the container logs for the mnode-svc-aiq-collector service on the mNode.

In /var/log/syslog:

Memory cgroup out of memory

Task in /docker/af508468f78f4d8fd1811193b19eeecc5da3e3bcb1e64f3835b600976974f257 killed as a result of limit

 