Issue

  • System cannot boot up after a L2 watchdog reset.

 Record 503: Tue Aug 23 17:00:20 2022 [IPMI Event.critical]: System reset
 Record 504: Tue Aug 23 17:00:20 2022 [IPMI Event.critical]: L2 watchdog action completed
 Record 505: Tue Aug 23 17:00:20 2022 [IPMI.notice]: L2 to L1 is 1(s) 158936(us)
 Record 506: Tue Aug 23 17:00:41 2022 [SP.notice]: Delaying L2_WDOG ASUP email for 120 seconds
 Record 507: Tue Aug 23 17:05:51 2022 [ASUP.notice]: First notification email | (REBOOT (watchdog reset)) CRITICAL | Send failed
 Record 508: Tue Aug 23 17:10:40 2022 [SP.critical]: Heartbeat stopped
 Record 509: Tue Aug 23 17:18:30 2022 [ASUP.notice]: Reminder email | (REBOOT (watchdog reset)) CRITICAL | Send failed

  • Multiple sensors are not in normal status or unreadable from system sensors output.

 Sensor Name      | Current    | Unit       | Status     | LCR       | LNC       | UNC       | UCR
 -----------------+------------+------------+------------+-----------+-----------+-----------+-----------
 CPU0_Temp_Margin | na         | degrees C  | na         | na        | na        | -10.000   | 0.000
 In_Flow_Temp     | 26.000     | degrees C  | ok         | 0.000     | 5.000     | 50.000    | 55.000
 Out_Flow_Temp    | 32.000     | degrees C  | ok         | 0.000     | 5.000     | 65.000    | 75.000
 PCI_Slot_Temp    | 31.000     | degrees C  | ok         | 0.000     | 5.000     | 60.000    | 70.000
 Smart_Bat_Temp   | 28.000     | degrees C  | ok         | 0.000     | 5.000     | 60.000    | 70.000
 CPU0_Error       | 0x0        | discrete   | Asserted   | na        | na        | na        | na     
 CPU0_Therm_Trip  | 0x0        | discrete   | Asserted   | na        | na        | na        | na     
 CPU0_Hot         | 0x0        | discrete   | Deasserted | na        | na        | na        | na
 Memory0_Hot      | 0x0        | discrete   | Deasserted | na        | na        | na        | na
 PCH_Hot          | 0x0        | discrete   | Deasserted | na        | na        | na        | na
 Ambient_Temp_1   | 24.000     | degrees C  | ok         | 0.000     | 5.000     | 47.000    | 52.000
 Ambient_Temp_2   | 24.000     | degrees C  | ok         | 0.000     | 5.000     | 47.000    | 52.000
 P5V_STBY         | 5.075      | Volts      | ok         | 4.246     | 4.343     | 5.661     | 5.807
 P3V3_STBY        | 3.280      | Volts      | ok         | 2.960     | 3.040     | 3.568     | 3.664
 P1V8_STBY        | 1.785      | Volts      | ok         | 1.630     | 1.659     | 1.950     | 1.969
 P1V2_STBY        | 1.193      | Volts      | ok         | 1.086     | 1.106     | 1.300     | 1.319
 P0V9_STBY        | 0.883      | Volts      | ok         | 0.805     | 0.854     | 0.951     | 0.999
 P5V              | 0.073      | Volts      | cr         | 4.246     | 4.343     | 5.661     | 5.807     
 P3V3             | 3.280      | Volts      | ok         | 2.960     | 3.040     | 3.568     | 3.664
 PVDDQ_DDR4_AB    | 0.000      | Volts      | cr         | 0.010     | 0.019     | 2.454     | 2.464     
 PVTT_DDR4_AB     | 0.000      | Volts      | cr         | 0.010     | 0.019     | 2.454     | 2.464     
 PVCCP_CPU0       | 0.000      | Volts      | cr         | 0.010     | 0.019     | 2.454     | 2.464     
 P3V3_BATT        | 3.184      | Volts      | ok         | 0.016     | 0.032     | 4.048     | 4.064

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.