ONTAP 9

Issue

  • SAS-connect subsystem in degraded state. Example:
::> system health subsystem show
Subsystem         Health
----------------- ------------------
SAS-connect       degraded
Environment       ok
...
  • Multiple EMS alerts. Example:
[node_name: nchmd: hm.alert.raised:alert]: Alert Id = DegradedShelfToShelfCabling_Alert , Alerting Resource = 012345678910 raised by monitor node-connect
[node_name: nchmd: hm.alert.raised:alert]: Alert Id = DegradedShelfToShelfCabling_Alert , Alerting Resource = 012345678911 raised by monitor node-connect
[node_name: nchmd: hm.alert.raised:alert]: Alert Id = DegradedShelfToShelfCabling_Alert , Alerting Resource = 012345678912 raised by monitor node-connect
[node_name: nchmd: hm.alert.raised:alert]: Alert Id = DegradedShelfToShelfCabling_Alert , Alerting Resource = 012345678913 raised by monitor node-connect
[node_name: nchmd: hm.alert.raised:alert]: Alert Id = DegradedShelfToShelfCabling_Alert , Alerting Resource = 012345678914 raised by monitor node-connect
[node_name: mgwd: callhome.hm.alert.major:alert]: Call home for Health Monitor process nchm: DegradedShelfToShelfCabling_Alert[012345678914].
  • System health alert example:
Monitor            node-connect    
Alert ID           DegradedShelfToShelfCabling_Alert    
Alerting Resource  012345678910    
Subsystem          SAS-connect    
Indication Time    Wed Apr 27 05:37:56 2022    
Perceived Severity Major    
Probable Cause     Cable_tamper    
Description    
Disk shelf 0a.shelf10 is connected only through 2 paths on IOM A and 2 paths on IOM B either to adjacent disk shelves or to the partner controller of the GobettiInfraTS-02 controller. 
Because controller node_name is connected to stack 0 through a quad-path configuration, disk shelf 0a.shelf10 must be connected with double-wide cabling to adjacent disk shelves or quad-path to the partner controller.    
Corrective Actions
1. Consult the guide applicable to your IOM12 disk shelf to review cabling rules and complete the SAS cabling worksheet for your system.
2. If disk shelf 0a.shelf10 is connected to another disk shelf, verify that disk shelf 0a.shelf10 is connected with double-wide cabling.
3. If disk shelf 0a.shelf10 is connected to the partner controller, verify that stack 0 containing disk shelf 0a.shelf10 is connected through a quad-path configuration. 
4. Contact technical support if the alert persists.    
Possible Effect     Inconsistent cabling might cause degraded performance.    
Acknowledge         false    
Suppress            false    
Policy              DegradedShelfToShelfCabling_Policy            
  • Incompatible SAS cable. Example:
slot 0: SAS Host Adapter 0a (PMC-Sierra PM8072 rev. C, SAS, <UP>)
      Mini-SAS HD Vendor:        FCI Electronics
      Mini-SAS HD Part Number:   10129376-3020LF+A
      Mini-SAS HD Type:          Passive Copper (unequalized) 4m ID:00
      Mini-SAS HD Serial Number: 1778214CR0028A00

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.