Skip to main content
NetApp Knowledge Base

PSU sensors show as 'Normal' when PSU is powered off

Views:
139
Visibility:
Public
Votes:
0
Category:
aff-series
Specialty:
hw
Last Updated:

Applies to

AFF A220
 

Issue

  • When PSU is powered off the sensors in ONTAP do not report any fault

Cluster1::> system environment sensors show -node Node-01 -state fault
There are no entries matching your query.

  • Sensors correctly report the PSU as NOT_PRESENT when physically removed

Cluster1::> system environment sensors show -node Node-01 -state fault
Node Sensor                 State Value/Units Crit-Low Warn-Low Warn-Hi Crit-Hi
---- --------------------- ------ ----------- -------- -------- ------- -------
Node-01
     PSU2 FRU               fault
                                  NOT_PRESENT
     PSU2 Present           fault
                                  NOT_PRESENT
2 entries were displayed.

 

 

 