Skip to main content
NetApp Knowledge Base

PCIe correctable error events for X4014A disks with a device status of 0xffff

Views:
227
Visibility:
Public
Votes:
0
Category:
aff-series
Specialty:
hw
Last Updated:

Applies to

  • AFF A800, AFF A250
  • Internal X4014A NVMe SSD

Issue

  • On AFF A800 or AFF A250 systems where internal X4014A NVMe SSD disks with a X4014S173A15TNTE drive string are idle, a PCIe correctable error event message might periodically be generated on the console and event log.
  • The message can appear in maintenance mode or while ONTAP is running.
  • It is least likely to occur if the drive is part of an aggregate that has active I/O.
  • It is more likely to occur if the drive is a spare drive.

The following are examples of these error messages:

In ONTAP:

Correctable IIO errors: IIO3: RPT(93,2,0): PCI Device 144d:a825 in slot 30 on Controller, 
Dv[a825](121,0,0) in slot 30: DevStaJul 11 17:46:02 [localhost:pcie.errors:notice]: 
PCI Express correctable error - IIO3: RPT(93,2,0): PCI Device 144d:a825 in slot 30 on 
Controller, Dv[a825](121,0,0) in slot 30: DevStatus(0xffff);

On the console during bootup:

Jul 15 13:18:34 [node1:pcie.errors:notice]: PCI Express correctable error - IIO3: 
RPT(93,0,0): SecStatus(RcvMstAbt), BrCtrl((0x13)); IIO3: RPT(93,2,0): SecStatus(RcvMstAbt), 
BrCtrl((0x13)); IIO7: RPT(215,0,0): SecStatus(RcvMstAbt), BrCtrl((0x13)); IIO7: RPT(215,2,0): 
SecStatus(RcvMstAbt), BrCtrl((0x13));

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.