Issue

  • EMS messages for one node in the cluster: 

Sat Dec 19 16:22:32 +0100 [CLUSTERBA-CTRLA: env_mgr: nvmem.battery.wrongCharge:alert]: The NVMEM battery charger is charging the battery even though the battery is not requesting to be charged. To prevent data loss, the system will shut down in 24 hours.
Sat Dec 19 16:23:27 +0100 [CLUSTERBA-CTRLA: env_mgr: callhome.battery.warning:alert]: Call home for BATTERY (wrong charge) WARNING.
... (repeated hourly)
Sun Dec 20 15:23:38 +0100 [CLUSTERBA-CTRLA: env_mgr: nvmem.battery.wrongCharge:alert]: The NVMEM battery charger is charging the battery even though the battery is not requesting to be charged. To prevent data loss, the system will shut down in 60 minutes.
Sun Dec 20 15:24:18 +0100 [CLUSTERBA-CTRLA: env_mgr: callhome.battery.warning:alert]: Call home for BATTERY (wrong charge) WARNING.
Sun Dec 20 16:22:30 +0100 [CLUSTERBA-CTRLA: env_mgr: monitor.shutdown.emergency:EMERGENCY]: Emergency shutdown: Environmental Reason Shutdown (Battery charging current failed)

Battery Charge Failed?       discrete fault   normal TRUE
Battery Capacity Message     discrete failed  failed
Bat Curr                     current  normal  -40 mA
Bat Charging State           discrete fault   normal WRONG_CHARGE

Jan  7 14:17:14 (none) env_mgr[1035]: Payload EMS: EMS_nvmem_battery_wrongCharge(in 24 hours)
Jan  7 14:17:46 (none) env_mgr[1035]: Payload EMS: EMS_callhome_battery_warning(BATTERY (wrong charge))
Jan  7 15:17:20 (none) env_mgr[1035]: Payload EMS: EMS_nvmem_battery_wrongCharge(in 23 hours)
Jan  7 15:17:47 (none) env_mgr[1035]: Payload EMS: EMS_callhome_battery_warning(BATTERY (wrong charge))
...

  • Service Processor events output: 

Record 992: Thu Jan  7 15:17:20 2021 [IPMI.notice]: b502 | 02 | EVT: 0301ffff | Attn_Sensor1 | Assertion Event, "State Asserted"
Record 993: Thu Jan  7 15:17:27 2021 [IPMI.notice]: b602 | 02 | EVT: 0300ffff | Attn_Sensor1 | Assertion Event, "State Deasserted"

 

  • The node goes down when the counter ends after 24 hours

 

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.