NS224 NSM100 Module boot device NONCRITICAL fault
Applies to
- NS224 shelf
- NSM100 shelf module
Issue
- EMS logs reporting shelf fault and may raise health alert:
[cluster-01: statd: monitor.shelf.warning:error]: Fault reported on disk storage shelf attached to channel 0x. Check fans, power supplies, disks, and temperature sensors.
[cluster-01: nchmd: hm.alert.raised:alert]: Alert Id = NoPathToNSMB_Alert , Alerting Resource = 12345678901234567890 raised by monitor node-connect
- Shelf module reports boot device fault in
storage show fault -v
command output (orSTORAGE-FAULT
AutoSupport section:
Enclosure Status: normal
Channel: 0x
Shelf: 1
Shelf Type: NS224NSM100
Module Type: NSM100
Enclosure:
Element Status Status Bytes Status Descriptions
1: OK 01,00,02,00 FAIL
Boot Device:
Element Status Status Bytes Status Descriptions
1 [NSM100 A] : OK 01,00,00,00
2 [NSM100 B] : NONCRITICAL 03,00,00,00