Skip to main content
NetApp Response to Russia-Ukraine Cyber Threat
In response to the recent rise in cyber threat due to the Russian-Ukraine crisis, NetApp is actively monitoring the global security intelligence and updating our cybersecurity measures. We follow U.S. Federal Government guidance and remain on high alert. Customers are encouraged to monitor the Cybersecurity and Infrastructure Security (CISA) website for new information as it develops and remain on high alert.
NetApp Knowledge Base

High sequential READ workload latency when using only onboard SAS ports

Views:
156
Visibility:
Public
Votes:
0
Category:
ontap-9
Specialty:
perf
Last Updated:

Applies to

  • AFF80x0
  • ONTAP 9
  • IOM6
  • SAS Adapters PMC-Sierra PM8001 and PM8072

Issue

  • High latency observed from SSDs during peak sequential READ workload.
  • EMS may report errors like below:

[?] Thu Aug 13 20:55:55 EDT [AFF80x0: pmcsas_timeout_1: sas.device.quiesce:debug]: Adapter 0c encountered a command timeout on enclosure services device 0d.01.99. Quiescing the device[?] Thu Aug 13 20:55:58 EDT [AFF80x0: pmcsas_timeout_1: sas.device.timeout:error]: Adapter 0c encountered a device timeout on Enclosure services device 0d.01.99.
[?] Thu Aug 13 20:55:58 EDT [AFF80x0: pmcsas_timeout_1: sas.adapter.debug:info]: params: {'debug_string': 'Level 0 timeout on virtual device: Hard resetting PHY: 0d.01.99 (0xfffff820aaab0040,0x1c,0/0)', 'adapterName': '0c'}
[?] Thu Aug 13 20:55:58 EDT [AFF80x0: scsi_cmdblk_strthr_admin: scsi.cmd.abortedByHost:error]: Enclosure services device 0d.01.99: Command aborted by host adapter: HA status 0x4: cdb 0x1c.

 

Scan to view the article on your device
CUSTOMER EXCLUSIVE CONTENT

Registered NetApp customers get unlimited access to our dynamic Knowledge Base.

New authoritative content is published and updated each day by our team of experts.

Current Customer or Partner?

Sign In for unlimited access

New to NetApp?

Learn more about our award-winning Support

 

  • Was this article helpful?