HA interconnect shows down on single link on AFF A800 using QSFP AVAGO
Applies to
- A800
- HA interconnect
- Dual 40/100G Ethernet T62100-CR
- FW revision 1.25.0.40 or older
Issue
- A single node in an HA pair shows a link down on the HA interconnect
Cluster::> set advanced
Cluster::*> ha interconnect port show
(system ha interconnect port show)
Physical Link
Link Layer Layer Physical Physical Active
Node Monitor Port State State Link Up Link Down Link
-------------- ------- ---- -------- --------- -------- --------- ------
Node-01 off
0 linkup active 2 1 true
1 linkup active 2 2 true
Node-02 off
0 disabled down 0 0 false
1 linkup active 1 0 true
-
sysconfig -a
does not populate the transceiver information for this port
slot 0: Dual 40/100G Ethernet T62100-MEZZ
e0a MAC Address: d0:39:ea:28:6a:5a (auto-100g_sr4-fd-up)
QSFP Vendor: AVAGO
QSFP Part Number: 332-00440
QSFP Serial Number: AF2047GU01Y
e0b MAC Address: d0:39:ea:28:6a:62 (auto-unknown-fd-down)
QSFP Vendor:
QSFP Part Number:
QSFP Serial Number: