Skip to main content
NetApp Knowledge Base

Aggregate offline after takeover due to missing disk drives X357_SLNGE3T8ATE

Views:
254
Visibility:
Public
Votes:
0
Category:
aff-series
Specialty:
hw
Last Updated:

Applies to

  • Disks X357_SLNGE3T8ATE running firmware NA54 and below
  • ONTAP 9

Issue

Aggregate offline following a takeover event

  • EMS log reports multiple disks failing with the following error:

scsi.cmd.pastTimeToLive:error]: Disk device 0c.11.17: request failed after try #1: cdb 0x5e:01.
disk.readReservationFailed:error]: Disk read reservation failed on 0c.11.17 CDB 0x5e:01 - SCSI:aborted command (b 2f 10)
diskown.errorDuringIO:error]: error 20 (disk operation timed out) on disk 0c.11.17 (S/N XXXXXXXX) while reading reservation state
raid.notify.on.non.persistent.failure:debug]: Received SDM_NOTIFY_ON_NON_PERSISTENT_FAILURE for disk uid, originating sysid XXXXXXXXX.
raid.notify.on.non.persistent.failure.fatal:debug]: Failing disk due to SDM_NOTIFY_ON_NON_PERSISTENT_FAILURE for disk 0c.11.17, error 22, reason 21, originating sysid XXXXXXXXX, owner 3.

raid.config.disk.not.responding:notice]: Disk 0c.11.15 Shelf 11 Bay 15 [NETAPP   X357_SLNGE3T8ATE NA54] S/N [XXXXXXXX] is not responding.

  • Aggregate fails to come online

raid.stripe.replay.volume.offline:notice]: Aggregate partner: aggr_2 is not online.
raid.assim.rg.missingChild:debug]: Aggregate partner:aggr_2, rgobj_verify: RAID object 0 has only 16 valid children, expected 23.
raid.assim.plex.missingChild:debug]: Aggregate partner:aggr_2, plexobj_verify: Plex 0 only has 0 working RAID groups (1 total) and is being taken offline
raid.assim.mirror.noChild:debug]: Aggregate partner:aggr_2, mirrorobj_verify: No operable plexes found.

  • SYSCONFIG-R section

*** This system has failed.
Any adapters shown below are those of the live partner
Aggregate aggr_2 (failed, raid_dp, partial, fast zeroed) (block checksums)
  Plex /aggr_2/plex0 (offline, failed, inactive)
    RAID group /aggr_2/plex0/rg0 (partial, block checksums)

      RAID Disk    Device      HA  SHELF BAY CHAN Pool Type  RPM  Used (MB/blks)    Phys (MB/blks)
      ---------    ------      ------------- ---- ---- ---- ----- --------------    --------------
      dparity     0c.11.12    0c    11  12  SA:B   0   SSD   N/A 3662580/7500964352 3662830/7501476528 (fast zeroed)
      parity      0b.12.12    0b    12  12  SA:A   0   SSD   N/A 3662580/7500964352 3662830/7501476528 (fast zeroed)
      data    FAILED          N/A                        3662580/ -
      data    FAILED          N/A                        3662580/ -
      data    FAILED          N/A                        3662580/ -
      data    FAILED          N/A                        3662580/ -
      data    FAILED          N/A                        3662580/ -
      data        0b.12.15    0b    12  15  SA:A   0   SSD   N/A 3662580/7500964352 3662830/7501476528 (fast zeroed)
      data        0c.11.16    0c    11  16  SA:B   0   SSD   N/A 3662580/7500964352 3662830/7501476528 (fast zeroed)
      data        0b.12.16    0b    12  16  SA:A   0   SSD   N/A 3662580/7500964352 3662830/7501476528 (fast zeroed)
      data    FAILED          N/A                        3662580/ -
      data        0b.12.17    0b    12  17  SA:A   0   SSD   N/A 3662580/7500964352 3662830/7501476528 (fast zeroed)
      data        0c.11.18    0c    11  18  SA:B   0   SSD   N/A 3662580/7500964352 3662830/7501476528 (fast zeroed)
      data        0b.12.18    0b    12  18  SA:A   0   SSD   N/A 3662580/7500964352 3662830/7501476528 (fast zeroed)
      data        0c.11.19    0c    11  19  SA:B   0   SSD   N/A 3662580/7500964352 3662830/7501476528 (fast zeroed)
      data        0b.12.19    0b    12  19  SA:A   0   SSD   N/A 3662580/7500964352 3662830/7501476528 (fast zeroed)
      data        0c.11.20    0c    11  20  SA:B   0   SSD   N/A 3662580/7500964352 3662830/7501476528 (fast zeroed)
      data        0b.12.20    0b    12  20  SA:A   0   SSD   N/A 3662580/7500964352 3662830/7501476528 (fast zeroed)
      data        0c.11.21    0c    11  21  SA:B   0   SSD   N/A 3662580/7500964352 3662830/7501476528 (fast zeroed)
      data        0b.12.21    0b    12  21  SA:A   0   SSD   N/A 3662580/7500964352 3662830/7501476528 (fast zeroed)
      data        0c.11.22    0c    11  22  SA:B   0   SSD   N/A 3662580/7500964352 3662830/7501476528 (fast zeroed)
      data        0b.12.22    0b    12  22  SA:A   0   SSD   N/A 3662580/7500964352 3662830/7501476528 (fast zeroed)
      data    FAILED          N/A                        3662580/ -
      Raid group is missing 7 disks.

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.