Correctable memory error FAQ
Applies to
- AFF
- FAS
- ASA
Answer
- Does the DIMM need to be replaced?
- Yes, if ONTAP (using Dynamic memory algorithm) sends a notification for an excessive correctable memory issue the memory should be replaced as soon as possible.
- Is the replacement disruptive?
- No, the memory is replaced performing takeover and giveback.
- How urgent is the replacement
- NetApp recommends replacing the DIMM at the earliest scheduled opportunity.
- How do I check the status of the RMA or Engineer?
- What is the procedure to replace the DIMM
- The guides for your platform can be found here. Select your platform from then DIMM from the Maintain section.
Platform | Replacement Procedure |
---|---|
AFF C190 | Replace a DIMM |
AFF A200 / FAS2600 | |
AFF A220 / FAS2700 | Replace a DIMM - AFF A220 and FAS2700 |
A250 / FAS500f | |
AFF A300 / FAS8200 | |
AFF A320 | |
AFF A400 / FAS8300 / FAS8700 | |
AFF A700 / FAS9000 |
Replace a DIMM - AFF A700 and FAS9000 Replace the NVRAM module and/or NVRAM DIMMs - AFF A700 and FAS9000 |
AFF A800 | |
AFF/FAS 80xx series |
- How long will the replacement take?
- Depending on platform the replacement might take up to 2 hours excluding prior preparations.
- What steps should be done on the system in advance of the replacement?
- A takeover of the node where the memory needs to be replaced can be performed.
- For a 2-node MetroCluster, a switchover will be required.
- Which DIMM needs to be replaced?
- The defective DIMM is called out in the case symptom
- It can be verified using the
memory dimm show
command
- What is the impact of leaving the identified DIMM in the system
- The DIMM is degraded and might result in an unexpected disruption of the node.
Additional Information
additionalInformation_text