Skip to main content
NetApp Knowledge Base

Adding a second NS224 shelf, changes first shelf ID to the serial number

Views:
1,109
Visibility:
Public
Votes:
3
Category:
disk-shelves
Specialty:
hw
Last Updated:

Applies to

  • NS224
  • ONTAP 9

Issue

  • Adding a second NS224 shelf to an existing stack, boots “slow”, showing the wrong ID 0 first and some unreadable characters later.
  • After some minutes, the added shelf NS224 shows the correct shelf ID 1.
  • The "storage shelf show" output for the previous existing shelf with the ID 0, changes the name from "1.0" to the s/n "1.SHFHUXXXXXXXXXX".

::> storage shelf show
                                                       Module Operational
       Shelf Name Shelf ID Serial Number   Model       Type   Status
----------------- -------- --------------- ----------- ------ -----------
1.SHFHUXXXXXXXXXX        0 SHFHUXXXXXXXXXX NS224NSM100 NSM100 Normal
              1.1        1 SHFHUYYYYYYYYYY NS224NSM100 NSM100 Normal
2 entries were displayed.

::> storage disk show
                     Usable           Disk    Container   Container
Disk                   Size Shelf Bay Type    Type        Name                                        Owner
---------------- ---------- ----- --- ------- ----------- ---------                                   --------
Info: This cluster has partitioned disks. To get a complete list of spare disk capacity use "storage aggregate show-spare-disks".
1.0.0                6.99TB     0   0 SSD-NVM shared      aggr_name_1, aggr_name_2                    node_name_2

1.0.5                6.99TB     0   5 SSD-NVM shared      aggr0_name_1, aggr_name_1, aggr_name_2      node_name_2
1.SHFHUXXXXXXXXXX.6  6.99TB     0   6 SSD-NVM shared      aggr0_name_2, aggr_name_1, aggr_name_2      node_name_1

1.SHFHUXXXXXXXXXX.11 6.99TB     0  11 SSD-NVM shared      aggr0_name_2, aggr_name_1, aggr_name_2      node_name_1
1.0.12               6.99TB     0  12 SSD-NVM shared      aggr0_name_1, aggr_name_1, aggr_name_2      node_name_2

1.0.17               6.99TB     0  17 SSD-NVM shared      aggr0_name_1, aggr_name_1, aggr_name_2      node_name_2
1.SHFHUXXXXXXXXXX.18 6.99TB     0  18 SSD-NVM shared      aggr0_name_2, aggr_name_1, aggr_name_2      node_name_1

1.SHFHUXXXXXXXXXX.23 6.99TB     0  23 SSD-NVM shared      -                                           node_name_1
1.1.0                6.99TB     1   0 SSD-NVM spare       Pool0                                       node_name_2

1.1.5                6.99TB     1   5 SSD-NVM spare       Pool0                                       node_name_2
1.SHFHUXXXXXXXXXX.18 6.99TB     1  18 SSD-NVM spare       Pool0                                       node_name_1

1.SHFHUXXXXXXXXXX.23 6.99TB     1  23 SSD-NVM spare       Pool0                                       node_name_1
36 entries were displayed.

  • At the node level CLI, just one node reports the "wrong" shelf ID:

node_name_1> storage show shelf
Shelf name:    0x.shelfSHFHUXXXXXXXXXX
Shelf id:      0
Channel:       0x
Module:        A

Shelf name:    0x.shelfSHFHUXXXXXXXXXX
Shelf id:      0
Channel:       0x
Module:        B


node_name_2> storage show shelf
Shelf name:    0x.shelf0
Shelf id:      0
Channel:       0x
Module:        A

Shelf name:    0x.shelf0
Shelf id:      0
Channel:       0x
Module:        B

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.