Applies to

  • AFF A400
  • 10/25 Gb/s network adapter

Issue

  1. Port shows link up or flapping with SFP but no cable inserted:
 
	slot 0: 10G/25G Ethernet Controller CX5-Mezz
		e0e MAC Address:    d0:22:ef:97:00:0d (auto-25g_sr-fd-up)
		    SFP Vendor:         AVAGO
		    SFP Part Number:    AFBR-725SMZ-NA1
		    SFP Serial Number:  AD2016G02TZ
vifmgr.port.monitor.failed: The "link_flapping" health check for port e0e (node node-01) has failed. The port is operating in a degraded state.
 
  1. CRC errors can be reported by the port:
 
[node-01: vifmgr: vifmgr.cluscheck.crcerrors:alert]: Port e0f on node node-01 is reporting a high number of observed hardware errors, possibly CRC errors.
 
RECEIVE
Total frames:        0  | Frames/second:       0  | Total bytes:         0
Bytes/second:        0  | Total errors:    66920  | Errors/minute:       0
Total discards:      0  | Discards/minute:     0  | Multi/broadcast:     0
Non-primary u/c:     0  | Errored frames:      0  | Unsupported Op:      0
CRC errors:      66918  | Runt frames:         0  | Fragment:        66914

 