Description

  • On these systems, the BIOS might map out memory DIMMs when errors are encountered, such as:

DIMM: B0 mapped out. BIOS MRC mapped out DIMM. Major Code 0x30 Minor Code 0x13

  • The BIOS message uses a two-letter code (DIMM: B0) to identify the DIMM with the error.
  • Example of PANIC message which would cause the DIMM mapped-out situation:

PANIC: ECC error at DIMM-13: CE-04-1944-427DADF8,ADDR 0x15e4014780,(Node(1), Memory controller(0), CH(1), DIMM(0), Rank(0), Bank Group(0), Bank(0x0), Row(0x15c80), Col(0x318)) Uncorrectable Machine Check Error at CPU13. ...
...
System rebooting...
...
Running full memory initialization.
DIMM F0: NVDIMM pending and destage progressing.....
PPR:Hard
PPR:Processing 0x1/0x0/0x1/0x0/0x0/0x0/0x0/0x0/0x15C80
PPR:Pre-PPR Row test PASS. dramMask = 0x0
PPR:Post-PPR Row test PASS. dramMask = 0x0
PPR:Sequence PASS
DIMM F0: NVDIMM with valid data and restage progressing.....
MEMORY WARNING: Major Code 0x30 Minor Code 0x2d DIMM:H0
DIMM:H0 mapped out. BIOS MRC mapped out DIMM. Major Code 0x0a Minor Code 0x03
DIMM:H0 mapped out. BIOS MRC mapped out DIMM. Major Code 0x0b Minor Code 0x1c
...
System DIMM configuration is not supported by AFF-A400
Halting...
...
LOADER-A>

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.