Skip to main content
NetApp Knowledge Base

Multi disk panic in FlexArray with third-party storage

Views:
146
Visibility:
Public
Votes:
0
Category:
v-series-flexarray
Specialty:
san
Last Updated:

Applies to

ONTAP 9.x

FlexArray setup

3PAR array 

Issue

  • A single disk went missing in a Flex Array with Raid 0 and it resulted in Multi disk Panic.
  • The Node panicked as it could not talk to that one disk which was part of the raid group and was not visible from any available paths

Event log: 

Panic string: aggr aggrname: raid volfsm, fatal disk error in RAID group with no parity disk. raid type raid0 in SK process config_thread on release 9.x (C)

 