cshm: UnsupportedSwitch_Alert for BES-53248 switch

Views:
832
Visibility:
Public
Votes:
3
Category:
fabric-interconnect-and-management-switches
Specialty:
hw
Last Updated:

Applies to

  • BES-53248 switch
  • ONTAP 9.8

Issue

  • Cluster was upgraded from a switchless to a switched configuration
  • Differnet Cluster switches were added
  • The switch is supported by Hardware Universe
  • In the EMS-LOG-FILE section of AutoSupport:

Wed Nov 17 09:13:33 CET [Cluster6-02: mgwd: callhome.hm.alert.major:alert]: Call home for Health Monitor process cshm: UnsupportedSwitch_Alert[Cluster6-sw1]

Wed Nov 17 09:33:33 CET [Cluster6-02: mgwd: callhome.hm.alert.major:alert]: Call home for Health Monitor process cshm: SwitchCommunityString_Alert[Cluster6-sw1]

  • system health subsystem show reports:

Cluster6::> system health subsystem show
Subsystem         Health
----------------- ------------------
Switch-Health     degraded

  • Output of system health alert show provides a probable cause

Cluster6::> system health alert show

           Node: Cluster6-01
           Resource: Cluster6-sw1
           Severity: Major
           Probable Cause: Ethernet switch "Cluster6-sw1" with IP address
                     "xx.x.xxx.xxx" is not reachable via SNMP. Incorrect
                     SNMP community string might be configured on the
                     Ethernet switch.
                        
           Node: Cluster6-01
           Resource: Cluster6-sw1
           Severity: Major
           Probable Cause: Unsupported Ethernet switch is detected.
  • The switches have the flag “cluster-network" via system switch ethernet show

Cluster6::> system switch ethernet show
    Switch                      Type               Address          Model
    --------------------------- ------------------ ---------------- ---------------
    Cluster6-sw2                cluster-network    xx.x.xxx.xxx     BES-53248
         Serial Number: 123456789
         ...    

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.