CRC error on Cluster Ports due to Port errors on Cluster Switch

Views:
514
Visibility:
Public
Votes:
0
Category:
fabric-interconnect-and-management-switches
Specialty:
nas
Last Updated:

Applies to

  • ONTAP 9
  • Cisco Cluster Interconnect Switch

Issue

  • In the EMS-LOG-FILE section of the AutoSupport, the port on node connected to the switch reports CRC errors
Thu Nov 04 02:30:48 +0100 [Node1: vifmgr: vifmgr.cluscheck.crcerrors:alert]: Port e0a on node Node1 is reporting a high number of observed hardware errors, possibly CRC errors
  • From IFSTAT output :-
    -- interface  e2a  (54 days, 7 hours, 16 minutes, 50 seconds) --
    
    connected to bond-sw-02(FDO26020KJB) port Ethernet1/10
    
    RECEIVE
    Total frames:     7264m | Frames/second:    1548  | Total bytes:     20720g
    Bytes/second:     4416k | Total errors:     1437  | Errors/minute:       0
     Total discards:      0  | Discards/minute:     0  | Multi/broadcast:  9402k
    Non-primary u/c:     0  | CRC errors:       1427  | Runt frames:         0
     Fragment:            0  | Long frames:         0  | Jabber:              2
     Length errors:       0  | No buffer:           0  | Xon:                 0
     Xoff:                0  | Pause:               0  | Jumbo:            2327m
    Noproto:             0  | Error symbol:        0  | Illegal symbol:      8
     Bus overruns:        0  | Queue drops:         0  | LRO segments:     5374m
    LRO bytes:       20524g | LRO6 segments:       0  | LRO6 bytes:          0
     Bad UDP cksum:       0  | Bad UDP6 cksum:      0  | Bad TCP cksum:       0
     Bad TCP6 cksum:      0  | Mcast v6 solicit:    0  | Lagg errors:         0
     Lacp errors:         0  | Lacp PDU errors:     0
    
    
    Node-15
    
    -- interface  e1a  (54 days, 5 hours, 2 minutes, 29 seconds) --
    
    connected to bond-sw-02(FDO26020KJB) port Ethernet1/1/1
    
    
    RECEIVE
    Total frames:     4798m | Frames/second:    1025  | Total bytes:     26784g
    Bytes/second:     5718k | Total errors:    31463  | Errors/minute:       0
     Total discards:      0  | Discards/minute:     0  | Multi/broadcast:  9009k
    Non-primary u/c:     0  | CRC errors:      31213  | Runt frames:         0
     Fragment:            0  | Long frames:       250  | Jabber:              0
     Length errors:       0  | No buffer:           0  | Xon:                 0
     Xoff:                0  | Pause:               0  | Jumbo:            3213m
    Noproto:             0  | Error symbol:        0  | Illegal symbol:      0
     Bus overruns:        0  | Queue drops:         0  | LRO segments:     2383m
    LRO bytes:       26564g | LRO6 segments:       0  | LRO6 bytes:          0
     Bad UDP cksum:       0  | Bad UDP6 cksum:      0  | Bad TCP cksum:       0
     Bad TCP6 cksum:      0  | Mcast v6 solicit:    0  | Lagg errors:         0
     Lacp errors:         0  | Lacp PDU
    
  • From the switch end, the high number of Input/Output errors were observed, output from show tech-support:
Ethernet1/4/1 is up
admin state is up, Dedicated Interface
  Hardware: 10000 Ethernet, address: cc90.70ee.774c (bia cc90.70ee.774c)
  MTU 1500 bytes, BW 10000000 Kbit , DLY 10 usec
  RX
    3908787286 unicast packets  103884 multicast packets  75257 broadcast packets
    3909318114 input packets  3409382136056 bytes
    351690 jumbo packets  0 storm suppression bytes
    0 runts  351686 giants  1 CRC  0 no buffer
    351687 input error  0 short frame  0 overrun   0 underrun  0 ignored
    0 watchdog  0 bad etype drop  0 bad proto drop  0 if down drop
    0 input with dribble  0 input discard
    0 Rx pause
  TX
    9604947077 unicast packets  1454349 multicast packets  3536215 broadcast packets
    9610809120 output packets  10785052005849 bytes
    872003 jumbo packets
    871479 output error  0 collision  0 deferred  0 late collision
    0 lost carrier  0 no carrier  0 babble  10093176 output discard
    0 Tx pause

Ethernet1/4/2 is up
admin state is up, Dedicated Interface
  Hardware: 10000 Ethernet, address: cc90.70ee.774d (bia cc90.70ee.774d)
  MTU 1500 bytes, BW 10000000 Kbit , DLY 10 usec
  RX
    3521803990 unicast packets  103884 multicast packets  75154 broadcast packets
    3522485765 input packets  2984871566565 bytes
    510507 jumbo packets  0 storm suppression bytes
    0 runts  502737 giants  0 CRC  0 no buffer
    502737 input error  0 short frame  0 overrun   0 underrun  0 ignored
    0 watchdog  0 bad etype drop  0 bad proto drop  0 if down drop
    0 input with dribble  0 input discard
    0 Rx pause
  TX
    8123951053 unicast packets  1454350 multicast packets  3536320 broadcast packets
    8130520023 output packets  8924134848266 bytes
    1579516 jumbo packets
    1578300 output error  0 collision  0 deferred  0 late collision
    0 lost carrier  0 no carrier  0 babble  4487495 output discard
    0 Tx pause

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.