Applies to

  • Cluster Interconnect Switch
  • Broadcom BES-53248 Switch
  • Non-MetroCluster Switch
  • EFOS upgrade to 3.7.0.4 and later

Issue

  • Inter-Switch Links (ISLs) and port channel marked as Down, after upgrading one BES-53248 Cluster Network Switch to EFOS 3.7.0.4 or later
# show port-channel all
Log.    Channel                     Admin       Mbr     Device/       Port Port
Intf    Name            Min  Link   Mode   Type Ports   Timeout       Speed     Active
------- --------------- ---- ------ ------ ---- ------- ------------- --------- -------
1/1     Cluster-ISL     1    Down   En.    Dyn. 0/55    actor/long    100G Full False
                                                        partner/long
                                                0/56    actor/long    100G Full False
                                                        partner/long

# show port all

                 Admin     Physical   Physical   Link   Link    LACP   Actor
Intf      Type   Mode      Mode       Status     Status Trap    Mode   Timeout
--------- ------ --------- ---------- ---------- ------ ------- ------ --------
0/1              Enable    10G Full   10G Full   Up     Enable  Enable long
0/2              Enable    10G Full   10G Full   Up     Enable  Enable long
0/3              Enable    10G Full   10G Full   Up     Enable  Enable long
0/4              Enable    10G Full   10G Full   Up     Enable  Enable long
....
0/55      PC Mbr Enable    100G Full             Down   Enable  Enable long
0/56      PC Mbr Enable    100G Full             Down   Enable  Enable long

  • AutoSupport generates alerts reporting switch ISLs are down, similar to:

HA Group Notification (Health Monitor process cshm: SwitchIfIslDownWarn_Alert[SW1/Slot: 0 Port: 55 100G - Level]) ALERT

HA Group Notification (Health Monitor process cshm: SwitchIfIslDownWarn_Alert[SW2/ Link Aggregate 1]) ALERT

  • If cluster LIFs are manually reverted to home ports with cluster interconnect ISLs down, node on which cluster LIFs were reverted has outage (LIFs and volumes on this node will not serve data) and its cluster apps go offline on that node

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.

 