  • Links do not come up between the cluster ports on the X1151 card and BES-53248 switch ports.
  • Switch port output example:

(switch)# show port 0/53-0/54
                 Admin     Physical   Physical   Link   Link    LACP   Actor
Intf      Type   Mode      Mode       Status     Status Trap    Mode   Timeout
--------- ------ --------- ---------- ---------- ------ ------- ------ --------
0/53             Enable    100G Full             Down   Enable  Enable long
0/54             Enable    100G Full             Down   Enable  Enable long

  • Node cluster port output example:

dbnass5215::> network port show -ipspace Cluster
                                                  Speed(Mbps) Health
Port      IPspace      Broadcast Domain Link MTU  Admin/Oper  Status
--------- ------------ ---------------- ---- ---- ----------- --------
e3a       Cluster      -                down 9000  auto/auto  -
e3b       Cluster      -                down 9000  auto/auto  -

  • ONTAP EMS messages:

ERROR netif.sfpNotSupported: The SFP+ or QSFP+ module (not supported ) installed in e3a is not supported with this network interface.