Skip to main content
NetApp Response to Russia-Ukraine Cyber Threat
In response to the recent rise in cyber threat due to the Russian-Ukraine crisis, NetApp is actively monitoring the global security intelligence and updating our cybersecurity measures. We follow U.S. Federal Government guidance and remain on high alert. Customers are encouraged to monitor the Cybersecurity and Infrastructure Security (CISA) website for new information as it develops and remain on high alert.
NetApp Knowledge Base

How to troubleshoot CRC errors with BES-53248 cluster switches

Views:
641
Visibility:
Public
Votes:
0
Category:
fas-systems
Specialty:
hw
Last Updated:

Applies to

  • Broadcom BES-53248 Cluster Switch

Description

  • Similar to Cisco Nexus Switches, the BES-53248 switch uses Cut-Through switching, which means it forwards received errors out of all ports. 
  • This can cause multiple cluster ports to show received CRC errors when only one link is faulty. 
  • The following steps will assist in isolating the port that may be causing the issue.

 