How to determine the NetApp part number for a power supply (PS / PSU) or fan for Brocade 6520, 6510, 6505, 5100, X6-4 and X6-8 switch
Applies to
- SAN
- MetroCluster
Description
Faulty power supply or fan reported on Brocade 6520, 6510, 6505 or 5100 switch:
- Faulty PS reported:
psshow :
Power Supply #1 is OK
Airflow Direction : Portside Exhaust (Reverse)
Power Supply #2 is faulty*
* = No system control access to power supply.
- Faulty fan reported:
fanshow :
Fan 1 is Ok, speed is 4071 RPM
Fan 2 is faulty
Fan 3 is Ok, speed is 4119 RPM
Fan 4 is Ok, speed is 18977 RPM
Fan 5 is Unknown
- Faulty power supply or fan reported on Brocade X6-4 and Brocade X6-8:
psshow :
Power Supply #1 is OK
V10N18, DUCXXXXXXHJ ,23-0000161-01,A0,DELTA,ECXXXXXXX42 ,00,DUXXXX8N
Power Supply #2 is faulty
V10N22, DUCXXXXXX1H ,23-0000161-01,A0,DELTA,ECXXXXXXX42 ,00,DUXXXX2N
fanshow :
Fan 1 is Ok, speed is 4067 RPM
Fan 2 is faulty
Fan 3 is Ok, speed is 4067 RPM
Brocade X6-4 Director: Two fan assemblies, nonport-side exhaust or intake, for 1+1 redundancy. Each assembly contains 2 fans for total of 4. System requires 3 out of 4 functioning fans for operation. One fan assembly can be hot-swapped, but must be replaced immediately.
Brocade X6-8 Director: Three fan assemblies, nonport-side exhaust or intake, for 2+1 redundancy. Each assembly contains 2 fans for total of 6. System requires 5 out of 6 functioning fans for operation. One fan assembly can be hot-swapped, but must be replaced immediately.