In response to the recent rise in cyber threat due to the Russian-Ukraine crisis, NetApp is actively monitoring the global security intelligence and updating our cybersecurity measures. We follow U.S. Federal Government guidance and remain on high alert. Customers are encouraged to monitor the Cybersecurity and Infrastructure Security (CISA) website for new information as it develops and remain on high alert.
NetApp Knowledge Base

Brocade switch reboot/hung with no reason listed

Views:
349
Visibility:
Public
Votes:
1
Category:
fabric-interconnect-and-management-switches
Specialty:
brocade
Last Updated:

Applies to

Brocade Switch

Issue

Brocade switch reboots and lists no reason in the output of `errdump -a`.
2021/01/13-22:27:54, [TS-1008], 166442, FID 128, WARNING, NetApp01, 10.237.4.57 Clock Server used instead of 10.237.4.58.
2021/01/14-10:04:27, [HAM-1004], 166443, CHASSIS, INFO, NetApp01_6510, Processor rebooted - Reset.
2021/01/14-10:04:41, [FV-1001], 166444, CHASSIS, INFO, NetApp01, Flow Vision daemon initialized.
2021/01/14-10:05:09, [FCR-1069], 166445, FID 128, INFO, NetApp01, The FC Routing service is enabled.
 
2021/11/18-11:30:24:252641, [EM-1034], 130201/128550, CHASSIS, ERROR, Brocade6510, PS 2 set to faulty, rc=2000e., OID:0x44200000, power.c, line: 759, comp:emd, ltime:2021/11/18-11:30:24:244273
2021/11/18-11:30:24:252850, [MAPS-1003], 130202/128551, FID 128, WARNING, CDCSTSPRD1-A, Power Supply 2, Condition=ALL_PS(PS_STATE==FAULTY), Current Value:[PS_STATE, FAULTY], RuleName=defALL_PSPS_STATE_FAULTY, Dashboard Category=Fru Health., raslogAction.c, line: 101, comp:md, ltime:2021/11/18-11:30:24:251077
2021/11/18-11:30:37:538708, [MAPS-1021], 130203/128552, FID 128, WARNING, CDCSTSPRD1-A, RuleName=defCHASSISBAD_PWR_CRIT, Condition=CHASSIS(BAD_PWR>=1), Obj:Chassis [ BAD_PWR,1] has contributed to switch status CRITICAL., switchStatusPol, line: 233, comp:md, ltime:2021/11/18-11:30:37:536626
2021/11 18-11:30:37:538962, [MAPS-1020], 130204/128553, FID 128, WARNING, CDCSTSPRD1-A, Switch wide status has changed from HEALTHY to CRITICAL., switchStatusPol, line: 273, comp:md, ltime:2021/11/18-11:30:37:537818
2021/11/18-11:30:38:013143, [EM-1037], 130205/128554, CHASSIS, INFO, Brocade6510, PS 2 is no longer faulted., OID:0x44200000, poll.c, line: 1212, comp:emd, ltime:2021/11/18-11:30:38:012512
2021/11/18-11:30:39:564773, [LOG-1000], 130207/128556, CHASSIS, INFO, Brocade6510, Previous message repeated 2 time(s)., OID:0x44200000, poll.c, line: 1212, comp:emd, ltime:2021/11/18-11:30:39:032329
2021/11/18-11:30:39:564992, [MAPS-1003], 130208/128557, FID 128, WARNING, CDCSTSPRD1-A, Power Supply 2, Condition=ALL_PS(PS_STATE==ON), Current Value:[PS_STATE, ON], RuleName=defALL_PSPS_STATE_ON, Dashboard Category=Fru Health., raslogAction.c, line: 101, comp:md, ltime:2021/11/18-11:30:39:563035

 

Scan to view the article on your device
CUSTOMER EXCLUSIVE CONTENT

Registered NetApp customers get unlimited access to our dynamic Knowledge Base.

New authoritative content is published and updated each day by our team of experts.

Current Customer or Partner?

Sign In for unlimited access

New to NetApp?

Learn more about our award-winning Support