Skip to main content
NetApp Knowledge Base

Brocade switch X6-8 reboot with "HQx_BROx6_07, Processor rebooted - Reset."error

Views:
150
Visibility:
Public
Votes:
0
Category:
thirdparty
Specialty:
brocade
Last Updated:

Applies to

  • Brocade switch X6-8
  • FOS v8.2.1c

Issue

Brocade switch X6-8 reboot with the following error in errdump log.
 
2022/04/25-17:07:21, [EM-1033], 189, SLOT 2 | CHASSIS, ERROR, HQx_BROx6_07, CP in WWN 1 set to faulty because CP ERROR asserted.
 
2022/04/25-17:07:21, [EM-1047], 190, SLOT 2 | CHASSIS, INFO, HQx_BROx6_07, CP in slot 1 not faulty, CP ERROR deasserted.
 
2022/04/25-17:07:21, [FV-1002], 191, SLOT 2 | FID 128, INFO, HQx_BROx6_07, Flow Vision Config Replay Completed Successfully.
 
2022/04/25-17:07:27, [MAPS-1201], 192, SLOT 2 | FID 128, INFO, HQx_BROx6_07, MAPS has started monitoring with DCBJ_policy policy.
 
cifications.
 
_SYNC,0] has contributed to switch status MARGINAL.
 
2022/04/25-17:07:33, [MAPS-1020], 195, SLOT 2 | FID 128, WARNING, HQx_BROx6_07, Switch wide status has changed from HEALTHY to MARGINAL.
 
2022/04/25-17:08:25, [HAM-1004], 196, SLOT 1 | CHASSIS, INFO, HQx_BROx6_07, Processor rebooted - Reset.
 
2022/04/25-17:08:25, [SRM-1002], 197, SLOT 1 | CHASSIS, INFO, HQx_BROx6_07, raslog keep alive period has been changed to 1.
 
2022/04/25-17:08:25, [FV-1001], 198, SLOT 1 | CHASSIS, INFO, HQx_BROx6_07, Flow Vision daemon initialized.
 
2022/04/25-17:08:33, [ESM-1002], 199, SLOT 1 | FID 128, INFO, HQx_BROx6_07, ESMd initialization done for service fcsw:0.
 
2022/04/25-17:08:46, [FSSM-1002], 200, SLOT 2 | CHASSIS, INFO, HQx_BROx6_07, HA State is in sync.
 
2022/04/25-17:08:46, [FSSM-1002], 201, SLOT 1 | CHASSIS, INFO, HQx_BROx6_07, HA State is in sync.
 
2022/04/25-17:09:01, [MAPS-1020], 202, SLOT 2 | FID 128, WARNING, HQx_BROx6_07, Switch wide status has changed from MARGINAL to HEALTHY.

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.

 

  • Was this article helpful?