Skip to main content
NetApp Response to Russia-Ukraine Cyber Threat
In response to the recent rise in cyber threat due to the Russian-Ukraine crisis, NetApp is actively monitoring the global security intelligence and updating our cybersecurity measures. We follow U.S. Federal Government guidance and remain on high alert. Customers are encouraged to monitor the Cybersecurity and Infrastructure Security (CISA) website for new information as it develops and remain on high alert.
NetApp Knowledge Base

BES-53248 Cluster Switch NDU failed upgrade to EFOS 3.7.0.4 and later

Views:
1,141
Visibility:
Public
Votes:
0
Category:
ontap-9
Specialty:
hw
Last Updated:

Applies to

  • BES-53248
  • Upgrading EFOS to 3.7.0.4 +
  • Cluster Interconnect Switch

Issue

  • After upgrading one BES-53248 Cluster Network Switch from EFOS 3.3.x.x or 3.4.x.x to EFOS 3.7.0.4 or 3.8.0.2, Inter-Switch Links (ISLs) and port channel are marked in a Down state.
# show port-channel all
Log.    Channel                     Admin       Mbr     Device/       Port Port
Intf    Name            Min  Link   Mode   Type Ports   Timeout       Speed     Active
------- --------------- ---- ------ ------ ---- ------- ------------- --------- -------
1/1     Cluster-ISL     1    Down   En.    Dyn. 0/55    actor/long    100G Full False
                                                        partner/long
                                                0/56    actor/long    100G Full False
                                                        partner/long

# show port all

                 Admin     Physical   Physical   Link   Link    LACP   Actor
Intf      Type   Mode      Mode       Status     Status Trap    Mode   Timeout
--------- ------ --------- ---------- ---------- ------ ------- ------ --------
0/1              Enable    10G Full   10G Full   Up     Enable  Enable long
0/2              Enable    10G Full   10G Full   Up     Enable  Enable long
0/3              Enable    10G Full   10G Full   Up     Enable  Enable long
0/4              Enable    10G Full   10G Full   Up     Enable  Enable long
....
0/55      PC Mbr Enable    100G Full             Down   Enable  Enable long
0/56      PC Mbr Enable    100G Full             Down   Enable  Enable long

  • AutoSupport generates alerts reporting switch ISLs are down, similar to:

HA Group Notification (Health Monitor process cshm: SwitchIfIslDownWarn_Alert[SW1/Slot: 0 Port: 55 100G - Level]) ALERT

HA Group Notification (Health Monitor process cshm: SwitchIfIslDownWarn_Alert[SW2/ Link Aggregate 1]) ALERT

  • If cluster LIFs are manually reverted to home ports with cluster interconnect ISLs down, node on which cluster LIFs were reverted has outage (LIFs and volumes on this node will not serve data) and its cluster apps go offline on that node
Scan to view the article on your device
CUSTOMER EXCLUSIVE CONTENT

Registered NetApp customers get unlimited access to our dynamic Knowledge Base.

New authoritative content is published and updated each day by our team of experts.

Current Customer or Partner?

Sign In for unlimited access

New to NetApp?

Learn more about our award-winning Support