Breakout cables from a Nexus 3232C result in cluster ports offline
Applies to
Cluster Interconnect Switch Nexus 3232C with 40GB to 10GB breakout cables
Issue
- Nexus 3232C ports show the breakout connection but shows a status of not connected. The Cluster ports on the controllers all show down.
- Example of
ifconfig
:
e0b: flags=8843<up,broadcast,running,simplex,multicast> metric 0 mtu 9000
options=6c07bb<rxcsum,txcsum,vlan_mtu,vlan_hwtagging,jumbo_mtu,vlan_hwcsum,tso4,tso6,lro,vlan_hwtso,linkstate,rxcsum_ipv6,txcsum_ipv6>
ether 00:a0:98:9d:bd:9e
hwaddr 00:a0:98:9d:bd:9e
media: Ethernet autoselect (autoselect)
status: no carrier
plugged: SFP/SFP+/SFP28 Unknown (Copper pigtail)
vendor: CISCO-TYCO PN: 2231256-2 SN: TED1903L330-CH1 DATE: 2015-01-12
- Example of
sysconfig -a
output with the standard Cisco breakout cable in place:
e0c MAC Address: 00:a0:98:9b:b2:d2 (auto-unknown-fd-down)
SFP Vendor: CISCO-TYCO
SFP Part Number: 2231256-2
SFP Serial Number: TED1834L761-CH2
- Note: Output will vary depending on the cable being used.