sldiag test reports "port e2a or e2b link may be down"
Applies to
- FAS8200
- ONTAP 9.6P3
Issue
- When performing "
sldiag device run
", e2a and e2b port are reported as "ERROR
" in Status.
Example:
*> sldiag device status
Device TestName StartDate EndDate Status LOOP
---------- ---------------- ------------------- ------------------- ---------- --------
nvmem NVMEM details Tue Mar 3 08:24:08 Tue Mar 3 08:24:08 PASSED 1/1
...
e2a NIC Packet Test Tue Mar 3 08:24:40 Tue Mar 3 08:27:04 ERROR 1/1
e2b NIC Packet Test Tue Mar 3 08:25:02 Tue Mar 3 08:27:04 ERROR 1/1
e2c NIC Packet Test Tue Mar 3 08:25:24 Tue Mar 3 08:27:46 PASSED 1/1
e2d NIC Packet Test Tue Mar 3 08:25:47 Tue Mar 3 08:28:18 PASSED 1/1
- "
port e2a or e2b link may be down
" is reported.
Example:
*> sldiag device status -long -state failed
TEST START ------------------------------------------
DEVTYPE: nic
NAME: NIC Packet Test
START DATE: Tue Mar 3 08:24:17 GMT 2020
STATUS: Aborted
STARTING: NIC Packet Test
port e2a or e2b link may be down
Interface: e2a
NIC Packet Test
END DATE: Tue Mar 3 08:27:48 GMT 2020
LOOP: 1/1
TEST END --------------------------------------------
- "
sysconfig -a
" shows "UP
" as e2a and e2b port.
Example:
slot 2: Quad Gigabit Ethernet Controller 82580
e2a MAC Address: 90:e2:ba:fb:8a:94 (auto-1000t-fd-up)
e2b MAC Address: 90:e2:ba:fb:8a:95 (auto-1000t-fd-up)
e2c MAC Address: 90:e2:ba:fb:8a:96 (auto-1000t-fd-up)
e2d MAC Address: 90:e2:ba:fb:8a:97 (auto-1000t-fd-up)
Device Type: 150E, PBA E68891-020
Firmware Version: 3.1d 0x80000271
Serial Number: 90E2BAFB8A94