In response to the recent rise in cyber threat due to the Russian-Ukraine crisis, NetApp is actively monitoring the global security intelligence and updating our cybersecurity measures. We follow U.S. Federal Government guidance and remain on high alert. Customers are encouraged to monitor the Cybersecurity and Infrastructure Security (CISA) website for new information as it develops and remain on high alert.
NetApp Knowledge Base

What is the difference of the PSU alert in ASUP between Shelf and Node

Views:
256
Visibility:
Public
Votes:
0
Category:
fas-systems
Specialty:
hw
Last Updated:

Applies to

  • FAS8200
  • FAS2620
  • DS212C

Answer

  • Shelf like DS212C or DS2246 raises the following ASUP alerts when PSU failure.

Example:

(SHLEF POWER INTERRUPTED) ERROR
(SHELF_FAULT) ERROR

 

  • Node like FAS8200 or FAS6XXX and FAS3XXX raises the following ASUP alerts when PSU failure.

Example:

(CHASSIS POWER SUPPLY OFF:PS1) ERROR
(CHASSIS POWER SUPPLY DEGRADED:PS1)ERROR

  • Node like FAS2XXX has onboard IOM and internal shelf, so it raises the following ASUP alerts when PSU failure.

Example:

(SHLEF POWER INTERRUPTED) ERROR
(SHELF_FAULT) ERROR
(CHASSIS POWER DEGRADED:Power Supply Status Critical:PSU1) ERROR

 