Skip to main content
NetApp Knowledge Base

Unresponsive Service Processor API service causing command timeout and truncated Autosupport

Views:
2,148
Visibility:
Public
Votes:
1
Category:
fas-systems
Specialty:
hw
Last Updated:

Applies to

  • FAS/AFF
  • ONTAP 9
  • Baseboard Management Controller (BMC)
  • Service Processor (SP)

Issue

  1. Autosupport collection for platform subsystem data times out after 120 seconds
cluster::*> system node autosupport manifest show -status *-limit -fields subsys,status,error,time-collected  -subsys !log_files -time-collected >120000
node           seq-num prio-num subsys   time-collected status error
-------------- ------- -------- -------- -------------- ------------------------------- -----
node-01        812     49       platform 125315         collection-truncated-time-limit
node-01        804     133      platform 125300         collection-truncated-time-limit
node-01        797     49       platform 125197         collection-truncated-time-limit
  1. Commands like system node power show and system node environment sensors show time out after 120 seconds:

cluster::*> system node environment sensors show -node node-01

Warning: Unable to list entries on node node-01. The Service Processor on node "node-01" is not reachable. Verify that the SP or BMC is online, verify that api-service is enabled on the SP or BMC, verify that the partner node is running, check if pings from SP or BMC to partner node work, check if hw-assist keep-alives are normal, check that network ports are configured correctly and are functional (up). Then, try the command again.

Warning: Unable to list entries on node node-01. Timeout: Operation "environment_sensors_iterator::next_imp()" took longer than 50 seconds to complete [from mgwd on node "node-01" (VSID: -1) to mgwd at 169.XXX.XX.XXX]

Error: show failed: Timeout: Operation "environment_sensors_iterator::next()" took longer than 50 seconds to complete [from mgwd on node "node-01" (VSID: -1) to mgwd at 169.XXX.XX.XXX]

cluster::> system node power show -node node-01

Error: The Service Processor on node "node-01" is not reachable. Verify
       that the SP or BMC is online, verify that api-service is enabled on the
       SP or BMC, verify that the partner node is running, check if pings from
       SP or BMC to partner node work, check if hw-assist keep-alives are
       normal, check that network ports are configured correctly and are
       functional (up). Then, try the command again.

OR
 
Warning: Unable to list entries on node node-01. SP API service is not available on node "node-01". 
    Check SP firmware version and Data Ontap(R) version.

Error: show failed: SP API service is not available on node
       "node-01". Check SP firmware version and Data Ontap(R) version.

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.