In response to the recent rise in cyber threat due to the Russian-Ukraine crisis, NetApp is actively monitoring the global security intelligence and updating our cybersecurity measures. We follow U.S. Federal Government guidance and remain on high alert. Customers are encouraged to monitor the Cybersecurity and Infrastructure Security (CISA) website for new information as it develops and remain on high alert.
NetApp Knowledge Base

System health alert reports AllPathToOneEndOfStack_Alert

Views:
58
Visibility:
Public
Votes:
0
Category:
fas-systems
Specialty:
hw
Last Updated:

Applies to

  • Clustered Data ONTAP
  • FAS8300

Issue

"system health alert show" reports AllPathToOneEndOfStack_Alert.

Example:

Monitor    node-connect
Alert ID    AllPathToOneEndOfStack_Alert
Alerting Resource    1
Subsystem    SAS-connect
Indication Time    Wed Nov 17 13:29:18 2021
Perceived Severity    Major
AutoSupport Triggered    true
Probable Cause    Cable_tamper
Corrective Actions   
1. Consult the guide applicable to your IOM12 disk shelf to review cabling rules and complete the SAS cabling worksheet for your system.
2. Connect controller CNSENAS07-01 to the first and last disk shelves of stack 1.
3. Verify that controller CNSENAS07-01 is cabled to IOM A and IOM B of stack 1.
4. Contact technical support if the alert persists.
Node ID    Node1
Enable Asup for This Alert    true
Alert Clear Time

 

Scan to view the article on your device
CUSTOMER EXCLUSIVE CONTENT

Registered NetApp customers get unlimited access to our dynamic Knowledge Base.

New authoritative content is published and updated each day by our team of experts.

Current Customer or Partner?

Sign In for unlimited access

New to NetApp?

Learn more about our award-winning Support