system health alert show reports AllPathToOneEndOfStack_Alert

Example:

Monitor    node-connect
Alert ID    AllPathToOneEndOfStack_Alert
Alerting Resource    1
Subsystem    SAS-connect
Indication Time    Wed Nov 17 13:29:18 2021
Perceived Severity    Major
AutoSupport Triggered    true
Probable Cause    Cable_tamper
Corrective Actions   
1. Consult the guide applicable to your IOM12 disk shelf to review cabling rules and complete the SAS cabling worksheet for your system.
2. Connect controller CNSENAS07-01 to the first and last disk shelves of stack 1.
3. Verify that controller CNSENAS07-01 is cabled to IOM A and IOM B of stack 1.
4. Contact technical support if the alert persists.
Node ID    Node1
Enable Asup for This Alert    true
Alert Clear Time

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.