Applies to

  • FAS2750
  • Baseboard Management Controller (BMC)11.3P2

Issue

  • Storage fault LED is on.
  • Overcurrent Protection Fault error event can be found in the following command output.

Example:

::> system controller service-event show
                           
Node             ID  Event Location                      Event Description
---------------- --- ----------------------------------  ----------------------
Clusternode-01
                 1   10G Port 1 in Controller A          Overcurrent Protection Fault

 

  • SP SHELF FAULT RQSTD error event can be found in the following command output.

Example:

::> system node run -node * storage show fault -v

Enclosure Status: normal
Channel: 0a
Shelf: 0
Shelf Type: DS224-12
Product Serial Number: xxxxxxxxxxxxxxx
Module Type: IOM12E

Vendor Unique Element 88-IOM12E: (PCM)
Element Status         Status Bytes  Status Descriptions
  1: OK                01,01,80,00   SP SHELF FAULT RQSTD
  2: OK                01,01,00,00   

 