FAS25XX does not boot after a watchdog event

Views:
1,054
Visibility:
Public
Votes:
0
Category:
fas-systems
Specialty:
hw
Last Updated:

Applies to

FAS25xx

Issue

  • The system cannot boot up after an L2 watchdog timeout hard reset.

Record 160: Tue Jun  2 17:51:15 2020 [IPMI Event.critical]: NMI
Record 161: Tue Jun  2 17:51:16 2020 [IPMI.notice]: ef03 | 02 | EVT: 0301ffff | Controller_Fault | Assertion Event, "State Asserted"
Record 162: Tue Jun  2 17:51:16 2020 [IPMI Event.critical]: L2 watchdog timeout hard reset
Record 163: Tue Jun  2 17:51:17 2020 [IPMI.notice]: f003 | 02 | EVT: 6fc104ff | System_Watchdog | Assertion Event, "Hard reset"
Record 164: Tue Jun  2 17:52:17 2020 [IPMI Event.critical]: System reset
Record 165: Tue Jun  2 17:52:17 2020 [IPMI Event.critical]: L2 watchdog action completed
Record 166: Tue Jun  2 17:52:17 2020 [IPMI.notice]: L2 to L1 is 1(s) 106658(us)
Record 167: Tue Jun  2 17:52:29 2020 [SP.notice]: Delaying L2_WDOG ASUP email for 120 seconds
Record 168: Tue Jun  2 17:54:34 2020 [ASUP.notice]: First notification email | (REBOOT (watchdog reset)) CRITICAL | Sent
Record 169: Tue Jun  2 17:59:31 2020 [SP.critical]: Heartbeat stopped
Record 170: Tue Jun  2 18:03:07 2020 [ASUP.notice]: Reminder email | (REBOOT (watchdog reset)) CRITICAL | Sent

  • Multiple sensors status are unreadable from system sensors output.

Sensor Name      | Current    | Unit       | Status     | LCR       | LNC       | UNC       | UCR
-----------------+------------+------------+------------+-----------+-----------+-----------+-----------
CPU0_Temp_Margin | na         | degrees C  | na         | na        | na        | -5.000    | 0.000     
In_Flow_Temp     | 31.000     | degrees C  | ok         | 0.000     | 10.000    | 75.000    | 80.000    
Out_Flow_Temp    | 28.000     | degrees C  | ok         | 0.000     | 10.000    | 87.000    | 92.000    
Memory_Hot       | na         | discrete   | na         | na        | na        | na        | na        
CPU_Hot          | na         | discrete   | na         | na        | na        | na        | na        
CPU_Cat_Error    | na         | discrete   | na         | na        | na        | na        | na        
CPU_Therm_Trip   | na         | discrete   | na         | na        | na        | na        | na        
CPU_VCC          | na         | Volts      | na         | 0.708     | 0.747     | 1.348     | 1.426     
CPU_1.05V        | na         | Volts      | na         | 0.892     | 0.941     | 1.154     | 1.203     
CPU_VTT          | na         | Volts      | na         | 0.931     | 0.989     | 1.213     | 1.261     
LM56_Temp        | na         | degrees C  | na         | 0.000     | 10.000    | 72.000    | 77.000    
CPU_1.5V         | na         | Volts      | na         | 1.271     | 1.348     | 1.649     | 1.727     
1G_1.0V          | na         | Volts      | na         | 0.854     | 0.902     | 1.096     | 1.154     
X540_0.8V        | na         | Volts      | na         | 0.689     | 0.728     | 0.873     | 0.912     
X540_0.67V       | na         | Volts      | na         | 0.572     | 0.611     | 0.728     | 0.766     
USB_5.0V         | na         | Volts      | na         | 4.253     | 4.495     | 5.492     | 5.759     
PCH_3.3V         | na         | Volts      | na         | 2.798     | 2.973     | 3.625     | 3.800     
SASS_1.0V        | na         | Volts      | na         | 0.854     | 0.902     | 1.096     | 1.145     
SASS_1.2V        | na         | Volts      | na         | 1.018     | 1.077     | 1.319     | 1.377     
IB_1.2V          | na         | Volts      | na         | 1.018     | 1.077     | 1.319     | 1.377

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.