Issue

Shelf IOM hardware fault due to: reference clock failure.

Example:
EMS Event Log:
Wed Apr 20 21:56:35 EDT [Netapp-08: dsa_worker2: ses.status.ModuleError:critical]: DS4486 (S/N SHABC1234000789) shelf 2 on channel 0a SAS expander error for SAS shelf electronics 1: critical status; Reference Clock Failure. This module is on the rear of the shelf at the top center, on shelf module A.
Wed Apr 20 21:56:44 EDT [Netapp-08: statd: monitor.shelf.fault:critical]: Fault reported on disk storage shelf attached to channel 0a. Check fans, power supplies, disks, and temperature sensors.


Also, you might notice all the disks on the shelf showing DIS/CLK under storage-expander within the ASUP.
DIS/CLK = PHY is disabled due to an expander reference clock error.

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.