In response to the recent rise in cyber threat due to the Russian-Ukraine crisis, NetApp is actively monitoring the global security intelligence and updating our cybersecurity measures. We follow U.S. Federal Government guidance and remain on high alert. Customers are encouraged to monitor the Cybersecurity and Infrastructure Security (CISA) website for new information as it develops and remain on high alert.
NetApp Knowledge Base

SP heart beat LED on with no failure detected

Views:
87
Visibility:
Public
Votes:
0
Category:
fas-systems
Specialty:
hw
Last Updated:

Applies to

  • FAS8200

Issue

  • system led show all shows that SP heart beat LED is on:

SP01-01*> system led show all
FRU LED ID 1 is off
FRU LED ID 2 is off
FRU LED ID 3 is off
FRU LED ID 4 is on
FRU LED ID 5 is off
...
FRU LED ID 28 is off

SP01-01*> system led show

Display status of the specified <FRU-LED-ID>.

<FRU-LED-ID>:
        1 - SP Controller Fault LED
        2 - SP Chassis Locate LED
        3 - SP System Fault LED
        4 - SP Heartbeat LED
        5 - SP Fan 1 Fault LED
        ...
        28 - SP RTC Battery Fault LED (Coin Cell Battery)
        all others are not valid

  • service-event show with no failure detected from both sp prompt and ONTAP prompt:

SP01-01*>system service-event show
   ID   FRU Description                                              Fault Reason
                
   ---  ------------------------                                     ------------------                 
Fault Lights On:

cluster::> system controller service-event show -instance
There are no entries matching your query.

 

Scan to view the article on your device
CUSTOMER EXCLUSIVE CONTENT

Registered NetApp customers get unlimited access to our dynamic Knowledge Base.

New authoritative content is published and updated each day by our team of experts.

Current Customer or Partner?

Sign In for unlimited access

New to NetApp?

Learn more about our award-winning Support