Skip to main content
NetApp Knowledge Base

SPLinkDownAlert on FAS8200/A300 with SP firmware 5.8

Views:
477
Visibility:
Public
Votes:
0
Category:
fas-systems
Specialty:
hw
Last Updated:

Applies to

  • FAS8200
  • AFF A300
  • Service Processor (SP) firmware version: 5.8
  • SP internal switch version:Version16-SB_XXII-ETHSW-RZL

Issue

  • System reports SPLinkDownAlert message:

Example:

Mon May 24 05:19:47 CST [Hostname: nphmd: hm.alert.raised:alert]: Alert Id = SPLinkDownAlert , Alerting Resource = SP Config raised by monitor controller

  • E0M link up, SP is online while no IP address from sysconfig -a:

Example:

Service Processor           Status: Online
  Firmware Version:   5.8
  Mgmt MAC Address:   
  Ethernet Link:      down, full duplex, auto-neg complete
  Using DHCP:         no
 IPv4 configuration:
  IP Address:         unknown
  Netmask:            unknown
  Gateway:            unknown
 IPv6 configuration:         Disabled

slot 0: Gigabit Ethernet I210
  e0M MAC Address:     (auto-1000t-fd-up)
  Device Type:        1533
  Firmware Version:   3.25-5.5 0x80000674

  • SP internal switch version is Version16-SB_XXII-ETHSW-RZL.

Example from "SP-LATEST-CONFIGURATION":

Check revision of programmable devices with revision of images bundled in SP (/usr/local/bin/check_fw_revision.sh)
==================================================
Versions that do not match will be printed.
==================================================
Ethernet switch version
==================================================
Version16 SB_XXII ETHSW RZL

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.