Skip to main content
NetApp Knowledge Base

Power supply firmware cannot be changed

Views:
202
Visibility:
Public
Votes:
0
Category:
not set
Specialty:
hw
Last Updated:

Applies to

  • AFF Series
  • FAS Series
  • Replaced Power Supply Unit (PSU)

Issue

storage shelf show shows a different firmware version from the previous one after replacing PSU.

Before Replacement:

Power Supply Units:
                                                     Crest  Power   Reset   PSU              Operational
 ID
Type Part#        Serial#         Power Rating   Factor Drawn   Capable Enabled Firmware Status           PSU Location
--- ---------------- --------------- -------------- ------ ------- ------- ------- -------- ---------------- ------------------------
  1 7D   114-00148+E0 PSQ09418470XXXX 913            0      0       false   true    0111     normal           rear of the shelf at thebottom left
  2 7D   114-00148+E0 PSQ09418470XXXX 913            0      0       false   true   0111     off              rear of the shelf at the bottom right

After Replacement:

Power Supply Units:
                                                     Crest  Power   Reset
PSU              Operational
 ID Type Part#        Serial#         Power Rating   Factor Drawn   Capable Enabled Firmware Status       PSU Location
--- ---- ------------ --------------- -------------- ------ ------- ------- ------- -------- ----------------------------------------
  1 7D   114-00148+E0 PSQ09418470XXXX 913            0      0       false   true    0111     normal   rear of the shelf at the bottom left
  2 98   114-00148+F1 PSQ09418470XXXX 913            0      0       false   true  0110     normal   rear of the shelf at the bottom right

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.