In response to the recent rise in cyber threat due to the Russian-Ukraine crisis, NetApp is actively monitoring the global security intelligence and updating our cybersecurity measures. We follow U.S. Federal Government guidance and remain on high alert. Customers are encouraged to monitor the Cybersecurity and Infrastructure Security (CISA) website for new information as it develops and remain on high alert.
NetApp Knowledge Base

Node is unresponsive on shutdown due to Service Processor (SP) internal serial port connection

Views:
299
Visibility:
Public
Votes:
0
Category:
fas-systems
Specialty:
hw
Last Updated:

Applies to

  • ONTAP 9
  • FAS/AFF
  • Service Processor (SP)

Issue

  • When rebooting a storage controller during ONTAP upgrade or other maintenance, it becomes unresponsive and unreachable in the cluster
  • Storage failover states the node is dumping core for many hours
  • The SP allows logging in, but shows no prompt to run commands to check state of the node
  • The storage controller is inspected physically to find an unknown device plugged into serial console port and after removing this cable, the node becomes responsive again

 