In response to the recent rise in cyber threat due to the Russian-Ukraine crisis, NetApp is actively monitoring the global security intelligence and updating our cybersecurity measures. We follow U.S. Federal Government guidance and remain on high alert. Customers are encouraged to monitor the Cybersecurity and Infrastructure Security (CISA) website for new information as it develops and remain on high alert.
NetApp Knowledge Base

Node in boot loop with partner up but not serving data

Views:
78
Visibility:
Public
Votes:
0
Category:
fas-systems
Specialty:
hw
Last Updated:

Applies to

  • ONTAP
  • Two node switchless AFF or FAS configuration

Issue

  • Node panics while in takeover of partner, and enters boot loop:
PANIC : prod/common/wafl/blkr/blkr.c:542: Assertion failure.
  • Further boot attempts result in:
PANIC : page fault (supervisor read data, page not present) on VA 0x410 cs:rip 0x20:0xffffffff8067192a rflags 0x10246
  • Node is unable to boot to maintenance mode or boot menu without panicking
  • This can occur during any takeover - including during ONTAP upgrade
  • Node panics just after printing a message similar to the following:
Warning: Freeing unused FAT sector 1663140 4 6c

 