NetApp FAS controller shutdowns with multiple chassis fan failed warnings, but only one chassis fan FRU is showing failed

Views:
2,987
Visibility:
Public
Votes:
1
Category:
fas-systems
Specialty:
hw
Last Updated:

Applies to

  • AFF
  • FAS

Issue

  • Controller shuts down with multiple fan failure even though only one field-replaceable unit (FRU) needs a replacement.
  • Autosupports similar to the following can be generated:
HA Group Notification (MULTIPLE CHASSIS FAN FAILED: System will shut down in 2 minutes) ERROR
HA Group Notification (Health Monitor process nphm: NphmCriticalFanFruFaultAlert[xxxxxxxxxxxx]) CRITICAL
HA Group Notification (CHASSIS FAN FRU FAILED: SysFan1 F1) ERROR
HA Group Notification (CHASSIS FAN FRU FAILED: SysFan1 F2) ERROR
  • EMS errors for chassis SysFan failure:

Jun 05 00:35:42 [cluster-n01:monitor.chassisFanFail.xMinShutdown:EMERGENCY]: Multiple Chassis Fan failure: System will shut down in 2 minutes.
Jun 05 00:36:00 [cluster-n01:monitor.globalStatus.critical:EMERGENCY]: Multiple fans has failed: SysFan1 F2, SysFan1 F1.
Jun 05 00:38:07 [cluster-n01:monitor.shutdown.emergency:EMERGENCY]: Emergency shutdown: Environmental Reason Shutdown (Multiple fans failed)

  • EMS errors for chassis IOfan failure:

Feb 27 14:06:51 [cluster-n01:monitor.chassisFanFail.xMinShutdown:EMERGENCY]: Multiple Chassis Fan failure: System will shut down in 2 minutes.
Feb 27 14:07:00 [cluster-n01:monitor.globalStatus.critical:EMERGENCY]: Multiple fans has failed: IOfan3 F1, IOfan3 F2.
Feb 27 14:09:21 [cluster-n01:monitor.shutdown.emergency:EMERGENCY]: Emergency shutdown: Environmental Reason Shutdown (Multiple IO fans failed)

  • SP/BMC system sensors appear FAN1_1 and Fan1_2 are na status.

Fan1_1           | na         | RPM        | na    | na        | 600.000   | 900.000   | na        | na        | na
Fan2_1           | 12600.000  | RPM        | ok    | na        | 600.000   | 900.000   | na        | na        | na
Fan3_1           | 12600.000  | RPM        | ok    | na        | 600.000   | 900.000   | na        | na        | na
Fan4_1           | 12600.000  | RPM        | ok    | na        | 600.000   | 900.000   | na        | na        | na
Fan1_2           | na         | RPM        | na    | na        | 600.000   | 900.000   | na        | na        | na
Fan2_2           | 12700.000  | RPM        | ok    | na        | 600.000   | 900.000   | na        | na        | na
Fan3_2           | 12700.000  | RPM        | ok    | na        | 600.000   | 900.000   | na        | na        | na
Fan4_2           | 12700.000  | RPM        | ok    | na        | 600.000   | 900.000   | na        | na        | na

 

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.

 