NVDIMMBadHealthAlert Reason: FIRMWARE error, on NVDIMM-equipped systems

Views:
4,651
Visibility:
Public
Votes:
3
Category:
aff-series
Specialty:
hw
Last Updated:

Applies to

  • ONTAP 9
  • AFF A800, AFF A400, AFF A320
  • FAS8700, FAS8300
  • NVDIMM
    • Health Status Explanation: NVDIMM FIRMWARE error

Issue

EMS:

Sun Jun 06 17:17:15 -0700 [NetApp1: nphmd: hm.alert.raised:alert]: Alert Id = NVDIMMBadHealthAlert , Alerting Resource = /dev/nvdimm0:NetApp1 raised by monitor controller

AutoSupport Section: NVDIMM-STATUS 

Total NVDIMM on this platform is 1
--------------------------------------------------
 DIMM(/dev/nvdimm0) Page:0 
--------------------------------------------------
0x0000: 00 0a 0a 01 01 00 21 3c   25 3c 25 34 34 00 00 00 
0x0010: 1f 2e 00 00 03 15 03 0b   68 81 02 00 68 81 1e 80 
0x0020: 05 80 78 80 05 00 00 40   1f ac 0d d0 07 a0 0f 90 
0x0030: 33 08 08 dc 05 10 80 00   00 00 70 03 00 00 00 00 
0x0040: 00 00 00 00 00 00 00 00   00 00 00 00 00 00 00 00 
0x0050: 00 00 00 00 00 00 00 00   00 00 00 00 00 00 00 00 
-----------------------------------------------------
--------------------------------------------------
 DIMM(/dev/nvdimm0):
--------------------------------------------------
	 Controller Ready: Yes 
	 Controller Busy: No 
	 Energy Policy managed by: HOST
	 Save_N Low During CSAVE: Yes
	 Save_N Enabled(ARMED): Yes
	 Data on the Flash: NotValid

	 Module is Health: No
	 Module Status(0x0040): NVDIMM FIRMWARE error
	 Flash Lifetime: 86%
	 Flash Lifetime Status: Normal

Example Health Alert:

::>system health alert show

Node NetApp1
Monitor controller
Alert ID NVDIMMBadHealthAlert
Alerting Resource /dev/nvdimm0:NetApp1
Subsystem Motherboard
Indication Time Sun Jun 06 17:17:15 2021
Perceived Severity Major
Probable Cause hardware_degrading
Description NVDIMM "NVDIMM-N 0 (DIMM-11)" on node "NetApp1" is indicating a degraded status.
Corrective Actions Contact technical support for assistance with NVDIMM module replacement.
Possible Effect Potential data loss as the NVDIMM becomes degraded.
Acknowledge false
Suppress false
Policy NVDIMMBadHealthPolicy
Acknowledger  
Suppressor  
Additional Information

Node: NetApp1
Unique Name: /dev/nvdimm0:NetApp1 
Device Name and DIMM Slot: /dev/nvdimm0
Health Status: degraded
Health Status Explanation: NVDIMM FIRMWARE error
Lifetime Status: NORMAL
Lifetime Status Explanation: None

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.