Skip to main content
NetApp Knowledge Base

In Errors Count from cluster port seen on Cluster switch

Views:
75
Visibility:
Public
Votes:
0
Category:
fas-systems
Specialty:
hw
Last Updated:

Applies to

  • FAS8200
  • CN1610

Issue

  • In Errors Count from cluster port seen on Cluster switch resulting in performance issue
Switch Name: Clus-switch1
Switch Type: cluster-network
Interface name: Slot: 0 Port: 4 10G - Level
In Error Count: 195241906
In Ucast Packet Count: 1898860469
In Non-Ucast Packet Count: 417863
In Error %: 2
In Error % (Conv int): 235
In Error % (decimal): 2.353582422295592  << -----------
Out Error Count: 0
Out Ucast Packet Count: 714261296
Out Non-Ucast Packet Count: 5347101
Out Error %: 0
Out Error % (Conv Int): 0
Out Error % (decimal): 0
In warning Count: 2
Out warning Count: 0
 
  • Cluster LIF reports as flapping in EMS log
[Node01: vifmgr: vifmgr.port.monitor.failed:error]: The "link_flapping" health check for port e0b (node Node01) has failed. The port is operating in a degraded state.
 
 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.