Skip to main content
NetApp Knowledge Base

High latency on FC LUN with IO WQE failure in EMS

Views:
773
Visibility:
Public
Votes:
0
Category:
fas-systems
Specialty:
san
Last Updated:

Applies to

  • ONTAP 9.x
  • FC LUNs
  • Brocade switches

Issue

  • High latency observed intermittently on a FC LUN
  • Brocade switch repeatedly reported link resets on a specific port due to credit loss.
  • Alternatively Netapp SFP shows RX.
  • Switch port is connected to a NetApp node's target port which frequently reported IO WQE failures in EMS log

Example:

Mon Feb 10 00:28:21 +03 [NODE01: fct_tpd_work_thread_0: fcp.io.status:debug]: STIO Adapter:10a IO WQE failure, Handle 0x2, Type 8, S_ID: 20253, VPI: 18, OX_ID: 263, Status 0x3 Ext_Status 0x1d

 

CUSTOMER EXCLUSIVE CONTENT

Registered NetApp customers get unlimited access to our dynamic Knowledge Base.

New authoritative content is published and updated each day by our team of experts.

Current Customer or Partner?

Sign In for unlimited access

New to NetApp?

Learn more about our award-winning Support