  • ONTAP 9.x
  • FC LUNs
  • Brocade switches

Issue

  • High latency observed intermittently on a FC LUN
  • Brocade switch repeatedly reported link resets on a specific port due to credit loss
  • Switch port is connected to a NetApp node's target port which frequently reported IO WQE failures in EMS log
  • Example:

Mon Feb 10 00:28:21 +03 [NODE01: fct_tpd_work_thread_0: fcp.io.status:debug]: STIO Adapter:10a IO WQE failure, Handle 0x2, Type 8, S_ID: 20253, VPI: 18, OX_ID: 263, Status 0x3 Ext_Status 0x1d

 